Through-Beam Edge Measurement Sensor (MU-DM2)
Through-beam edge measurement · ±0.2 % F.S. at 100 mm

Through-Beam Edge Measurement Sensor (MU-DM2)

A 660 nm laser through-beam pair that reports edge position across a 5 mm window or strip width across a 10 mm window, with 0.25 µm repeat and a 200 µs sampl

Model MU-DM2-A / MU-DM2-485 + LE-010 · Brand LE Raun · Category: Laser Displacement & Profile

Measuring range5 / 10 mm
Repeat0.25 µm
Sampling200 µs
Mounting distance≤ 300 mm

Overview

The MU-DM2 is not a distance sensor. It is a shutter: the emitter floods the receiver with a 3 × 14 mm laser band, the material interrupts part of it, and the controller measures how much of the band is covered. That makes the reading independent of the material's colour, gloss or thickness — only the edge position matters.Two evaluation modes come from the same signal. In edge mode the controller reports where the edge sits inside a 5 mm window, which is what a web guide needs. In width mode it reports the full covered width inside a 10 mm window, which is what a slitting line needs. The 485 variant puts the value on a bus so several heads can share one cable run.The head is rated for a mounting distance of up to 300 mm and the linearity figure is quoted at 100 mm, so keep the optics as close to the roller as the machine allows. Temperature drift of ±0.02 % F.S./°C means a cold start in winter will read differently from an afternoon shift — allow a warm-up period before you calibrate.

Application scenarios

01

Web edge guiding on a printing press

The head reports edge position to the guide controller, which steers the unwind so the print register stays inside tolerance.

02

Slitting and rewinding

Measures strip width between the knives and flags a drift before the coil is wound out of specification.

03

Sheet-metal blank position

Checks that the blank is centred in the press before the ram comes down.

04

Glass, foil and film edges

Through-beam geometry does not depend on the surface finish, so it holds on clear film and mirror-finish foil where a triangulation sensor would not.

05

Coil diameter and lap detection

The edge signal is used to count laps or to follow the outside diameter of a winding coil.

Industries
  • Printing
  • Packaging
  • Steel and aluminium
  • Glass
  • Battery

Technical specifications

ControllerMU-DM2-A (analog) · MU-DM2-485 (RS485)
Sensor headLE-010
Light sourceRed semiconductor laser, 660 nm
Sensor-head mounting distanceMax. 300 mm
Measuring rangeEdge mode 5 mm · Width mode 10 mm
Laser classClass II (IEC / JIS)
Spot size3 × 14 mm
Linearity accuracy±0.2 % F.S. at a mounting distance of 100 mm (25 mm span)
Repeat accuracy0.25 µm
Sampling period200 µs
Temperature drift±0.02 % F.S./°C
IndicatorsTransmitter power (green) · receiver power (green) · alarm (red)
Supply voltage10–30 V DC ±10 %
Measuring principleLaser triangulation for short range, time-of-flight for long range
Linearity±0.1 % F.S. on the precision models
Sampling rateUp to 1 kHz on the fast models
InterfaceAnalogue 4–20 mA / 0–10 V, RS485, or digital switching outputs
ProtectionIP65 / IP67 aluminium housing

Dimensions

ItemValue
Emitter / receiver42 mm (emitter) / 36.5 mm (receiver) optical depth
Cable300 mm to M12 4-pin
Controller76.7 × 28.5 × 17 mm, mounting 18.8 / 36.6 mm, 10.5 mm stand-off

The head is the 61 mm block that straddles the edge; the controller is the 76.7 mm box that holds the threshold and the output — mount the head on the line and the controller on the frame, 300 mm apart.

Wiring & output

ConnectionFunction
Blue0 V
BlackSwitching output / alarm
WhiteAnalogue output (4–20 mA or 0–10 V)
ShieldEarth — bond at the controller end only

How to specify

  1. 01

    Fix the range first

    Triangulation covers a few millimetres to about a metre with µm resolution; beyond that the time-of-flight models take over at millimetre resolution. Do not ask a 10 mm-range sensor to measure at 500 mm — the spot has already walked off the receiver.

  2. 02

    Check what the spot lands on

    A shiny machined face sends the beam away from the receiver, a black rubber part absorbs it, and a transparent film lets it through. Blue-laser models are the answer for hot, red-glowing or organic surfaces; a 45° mounting removes most mirror reflections.

  3. 03

    Choose the interface from the controller

    Analogue for a fast control loop, RS485 when several sensors share one bus or when the reading has to be logged, switching output for a simple go/no-go.

  4. 04

    Allow for the environment

    A 1 µm sensor is only as good as its bracket. Thermal growth of an aluminium bracket over 10 °C is more than the repeatability of the sensor; use cast iron, granite or a short, stiff bracket.

Why this series

Edge and width from the same pair

The emitter and receiver straddle the material; the controller reports either where the edge sits inside the 5 mm window or how wide the strip is inside the 10 mm window. One mounting, two measurements.

200 µs sampling on a moving web

At 200 µs per sample the head keeps up with a web that is moving fast enough to blur a camera — which is the reason through-beam edge sensors still sit on printing and slitting lines.

The head stays small, the electronics stay in the cabinet

Splitting sensor head from controller lets the optics be a 20 mm block next to the roller while the terminals, the analog scaling and the RS485 address live in the enclosure.

Questions

Does the colour of the material affect the measurement?

No. The controller measures the shadow cast on the receiver, so black rubber, white paper and clear film all block the beam the same way. The limit is opacity: a material that lets a significant part of the 660 nm beam through will make the edge look soft.

What is the difference between the -A and the -485 controller?

The -A gives an analog voltage or current proportional to the edge position or width, for a drive or a PLC analog card. The -485 puts the same value on an RS485 bus, which is what you want when several heads sit on one machine and you would rather not run an analog cable to each.

Can I use one head for both edge and width?

Yes, the mode is a controller setting, not a different sensor head. You cannot read both at the same instant from one controller, but a second controller on the same head type covers the other axis.

Need a quotation for Through-Beam Edge?

Send your application details or the guard opening dimensions and we will specify the right model and configuration for your machine.

LE Raun

LE Raun is a high-tech enterprise specializing in R&D, production, and sales of industrial sensors and automation solutions. We are committed to providing cutting-edge sensing technology for smart manufacturing.

Contact Us

  • 10th Floor, Building 5, Minghu Zhigu Industrial Park, Fenghuang Subdistrict, Guangming District, Shenzhen, Guangdong, China
  • sensor01@leraun.com
  • +86 18818997341
© 2026 LE Raun. All rights reserved.
Contact Us
We will contact you within 24 hours.
We don't share your data