CNC machine tools
Safety contacts plus auxiliary feedback to the CNC for door-state display.

Electromagnetic interlocks with 2, 4 or 6 contacts and a 1300 N locked-state tensile strength — for machine tools that need more contacts than a basic interl
Model QSD-K6 / QSD / SDP · Brand LE Raun · Category: Safety Door Locks & Interlocks
Three contact configurations share one housing family: QSD-K6 with six contacts, QSD with two and SDP with four. All three lock with 1300 N of tensile strength, carry a 10 A thermal rating and switch AC-15 / DC-13 loads at 3 A.The extra contacts are what machine builders usually need: two for the safety circuit, plus auxiliary contacts to tell the PLC the door state, drive a lamp or interlock a second axis — without adding a separate switch and a second actuator on the door.
Safety contacts plus auxiliary feedback to the CNC for door-state display.
Multi-contact interlock on the mould-area guard.
Door monitoring where the PLC also needs a door-closed signal.
Interlocks the tool-change and load openings with separate auxiliary contacts.
Where a single switch has to report state to both the safety relay and the PLC.
| Models | QSD-K6-□□□□□ (6 contacts) · QSD-□□□□□ (2 contacts) · SDP-□□□□□ (4 contacts) |
|---|---|
| Housing material | Flame-retardant Pa66 |
| Contact material | Copper contacts |
| Tensile strength in locked state | 1300 N |
| Rated insulation voltage | 300 V |
| Rated impulse withstand voltage | 4.0 kV |
| Rated thermal current | 10 A |
| Utilization category | AC-15 / DC-13 |
| Rated operational current | 3 A |
| Forced release distance | ≥10 mm |
| Permissible operating speed | 0.05–0.5 m/s |
| Protection level | IP67 (per EN 60947-5-1, except for key-actuation aperture) |
| Product application | Suitable for CNC machine tools, injection-moulding equipment, semiconductor manufacturing equipment, etc. It ensures that the machine does not perform hazardous movements when the safety guard door is opened. |
| Contact resistance | ≤25 mΩ |
| Mechanical life | 1,000,000 operations |
| Electrical life | 500,000 operations |
| Operating frequency | 0.05–1 Hz (max. 120 operations per minute) |
| Ambient temperature | −25 … +80 °C, no icing |
| Item | Value |
|---|---|
| Actuator entry | 0.1 – 0.3 mm gap, centred to ±1 mm |
| Door-chain radius | R ≥ 300 mm for the chain or hinge used to carry the actuator |
| Cable | 2 m, direct outlet |
The head unscrews and turns so the cable can leave in any of four directions — set that before you drill, because the 4 screws are the only fixing points on the body.
| Terminal | Contact |
|---|---|
| 21 – 22 | NC, positive opening (second circuit) |
| 33 – 34 | NO |
| 41 – 42 | NO (where fitted) |
Monitoring only (mechanical interlock) is enough where the machine stops within the time the door needs to open. Locking is required where a spindle, press or robot arm keeps moving after the stop command.
Mechanical actuation is the simplest and cheapest. RFID and magnetic coding resist defeat with a spare actuator, tolerate misalignment and are the usual choice on washdown or vibrating guards.
Count the circuits: two NC for a dual-channel safety input, one NO for the door-closed signal to the PLC, plus one more NO if the lock state has to be reported separately.
Fzh is the force the lock withstands before the guard can be pulled open. Large sliding guards and guards with a long lever need the 2,000 N class rather than the 1,300 N class.
The actuator swings on the door hinge; the catalogue gives the minimum door radius for each model. Below that radius the actuator will bind and the switch will wear out.
2, 4 or 6 contacts in the same footprint, so the panel layout does not change between machine variants.
Holds the guard against the load a heavy door puts on the bolt.
Sealed to EN 60947-5-1 for coolant and chip environments.
Two contacts are enough for a simple series safety circuit. Choose 4 or 6 when the PLC also needs door-state feedback, a lamp, or a second interlocked axis.
Yes — 1300 N in the locked state for QSD-K6, QSD and SDP.
Rated operational voltage is 400 V for the 2- and 4-contact versions and 240 V / 30 V / 250 V for the 6-contact version, at 3 A operational current.
Send your application details or the guard opening dimensions and we will specify the right model and configuration for your machine.