LE-S3012N Safety Relay Module (Manual Start)
Safety Relay · Manual Start

LE-S3012N Safety Relay Module (Manual Start)

A dual-channel safety relay module for light curtain input, category 4 to EN ISO 13849-1 and safety level 3 to IEC 61508 / IEC 62061. Manual start version, 2

Model LE-S3012N · Brand LE Raun · Category: Safety Relay Modules

Safety category4 (EN ISO 13849-1)
Safety level3 (IEC 61508/62061)
Start-up modeManual start
Protection levelIP40 (terminals IP20)

Overview

The LE-S3012N is a dual-channel safety relay module for use with safety light curtains. It carries safety category 4 to EN ISO 13849-1 and safety level 3 to IEC 61508 / IEC 62061, and is built to EN ISO 13849-1, EN ISO 13849-2, EN 62061, IEC 61508 and IEC 62061.This is the manual start version: after the light curtain field is cleared the machine needs a separate start command. Module consumption is ≤2 W at 24 V DC, the output is protected by a built-in resettable fuse, minimum permissible load is 10 V DC / 10 mA, rated insulation voltage 300 V AC, and mechanical durability is ≥5,000,000 cycles. Operating range is −10 to +55 °C, non-condensing, in an IP40 (terminals IP20) housing.

Application scenarios

01

Manual restart after access

The machine waits for a deliberate start command once the field is clear — the default where an operator steps inside the guarded area.

02

Robot cell load/unload

Prevents the cell restarting while a person is still at the fixture.

03

Press with manual restart

Interfaces a light curtain to a press control circuit with a supervised restart.

04

Retrofit of older machines

Adds a monitored dual-channel relay stage to a machine that has none.

05

Guarded test stations

Where an engineer works inside the guard during setup.

Industries
  • Machine tools
  • Automotive
  • Robotics
  • Packaging

Technical specifications

ModelLE-S3012N
Start-up modeManual start
Compliant standardsEN ISO 13849-1 · EN 62061 · EN ISO 13849-2 · IEC 61508 · IEC 62061
Corresponding safety categorySIL 3 / PL e (Cat. 4); SIL 2 / PL d (Cat. 3) on reduced configs
Safety level3 (IEC 61508 / IEC 62061)
Module power consumption≤2 W (at 24 V DC)
Power supply & output protectionBuilt-in power protection
Minimum permissible load10 V DC / 10 mA
Rated insulation voltage300 V AC (reinforced / double insulation)
Vibration resistance10–55 Hz, single amplitude 0.35 mm
Protection levelIP40 (terminals IP20)
Mechanical durability≥5,000,000 cycles
Operating ambient temperature−10 to +55 °C (non-condensing)
Product applicationsSuitable for safety light curtain input. Performs dual-signal monitoring for emergency stop and safety switches on machinery and machine tools.
StandardsEN ISO 13849-1:2015, EN ISO 13849-2:2012, EN 62061:2015
Performance levelPLe / SIL 3, Category 4 architecture
Safety outputs3 NO contacts (13–14, 23–24, 33–34)
Signal output1 transistor output (41–42)
Contact ratingAC-15 3 A / 240 VAC, DC-13 1 A / 24 VDC
Conventional thermal current6 A
Contact materialAgSnO₂ with 2 µm Ag plating, silver-alloy contacts
Contact resistance≤100 mΩ
Electrical life100,000 operations
Mechanical life≥5,000,000 operations
Operating frequency0.5 Hz
Release time≤10 ms after power-off (status-LED delay excluded)
Rated impulse withstand2,500 V (1.2/50 µs)
TerminalsRemovable blocks, 2 × 1.5 mm² solid or 2 × 1 mm² stranded
Mounting35 mm DIN rail
Indication3 green LEDs — power, channel 1, channel 2

Dimensions

ItemValue
Height114.5 mm
Depth23 mm
EnclosureIP40, DIN-rail module
Weightapprox. 230 g

The 23 mm is the rail width — one slot — so a bank of these sits side by side without wasting panel space; the manual start is what makes it the choice for guarding that must be reset by an operator.

Wiring & output

TerminalFunction
S11 / S12Safety input, channel 1 — light curtain OSSD or first contact of a two-channel device
S21 / S22Safety input, channel 2 — second channel for dual-channel devices
13–14Safety output 1, NO, closed when both channels are healthy
23–24Safety output 2, NO
33–34Safety output 3, NO
41–42Transistor signal output for the PLC (state mirror)
SB1 / SB2Start / reset button, and two-hand control inputs on the two-hand module
KM1 / KM2External contactor feedback (EDM) — opens the enable path if a contactor welds

How to specify

  1. 01

    Count the safety outputs

    Every module has three NO safety outputs and one transistor signal output. Two outputs normally go to the two contactors of the main circuit, the third can report to the PLC or drive a second axis.

  2. 02

    Match the start mode to the risk assessment

    Manual start needs a deliberate reset after the field is clear; automatic start re-enables as soon as the field is clear and is only allowed where the operator cannot stand inside the guarded area. The two-hand module additionally requires both buttons within 0.5 s.

  3. 03

    Check the contact rating against the contactors

    3 A / 240 VAC is enough for the coil of a 24 VDC contactor but not for a large AC coil — use an interposing contactor or a force-guided pair.

  4. 04

    Wire the feedback loop

    The EDM input must see the NC auxiliary contacts of both switching contactors, otherwise a welded contact will not be detected and the module cannot reach Category 4.

Why this series

Category 4 architecture

Corresponding safety category 4 to EN ISO 13849-1, with safety level 3 according to IEC 61508 / IEC 62061.

Protected output

Built-in resettable fuse protects the power supply and the output circuit — no replaceable fuse to stock.

DIN-rail module

A compact housing for standard cabinet mounting, rated IP40 (terminals IP20) for installation inside an enclosure.

Questions

What does “manual start” mean?

The relay requires a deliberate start action after the protective field is cleared, rather than restarting the machine automatically. This is the usual choice where an operator stands inside the guarded area during setup.

Can it monitor an emergency stop as well?

The module performs dual-signal monitoring for emergency stop and safety switches on machinery and machine tools, and is intended for safety light curtain input.

What supply does it need?

24 V DC, with ≤2 W module power consumption and a built-in resettable fuse on the power supply and output.

Need a quotation for LE-S3012N Safety?

Send your application details or the guard opening dimensions and we will specify the right model and configuration for your machine.

LE Raun

LE Raun is a high-tech enterprise specializing in R&D, production, and sales of industrial sensors and automation solutions. We are committed to providing cutting-edge sensing technology for smart manufacturing.

Contact Us

  • 10th Floor, Building 5, Minghu Zhigu Industrial Park, Fenghuang Subdistrict, Guangming District, Shenzhen, Guangdong, China
  • sensor01@leraun.com
  • +86 18818997341
© 2026 LE Raun. All rights reserved.
Contact Us
We will contact you within 24 hours.
We don't share your data